Ãîëîâíà |
Test
The front panel BITE test only operates when the airplane is on the ground.
Momentarily push the test switch on the front of the RA receiver / transmitter to start a self test. Monitor the front panel for these results:
- Time = 0 seconds - all front panel LEDs come on red
- Time = 2 seconds - LRU STATUS LED changes to green
- Time = 4 seconds - all front panel LEDs go off
- Time = 6 seconds - applicable LEDs come on to show a normal (green) or fault (red) condition
- Time = 36 seconds - Front panel LEDs go off.
RA SYSTEM - FLIGHT COMPARTMENT BITE DISPLAY